600V Class Indoor Voltage Transformers 3 Phase

3 Phase Voltage Transformers

3 Ø Transformers are for applications with 100% of rated primary voltages designed for line to line operation but may also be used in a line to neutral or line to ground configuration at 58% of rated voltage.

MODEL / ACCURACY CLASS / THERMAL RATING / VOLTAGE RATIOS

SORTED BY VA RATING BELOW

__________________________________________________________________________________________________________________________________

469    (-/+ 1 % at 5 VA, 60 Hz, 40 VA @ 30 Deg C, 69.3 to 600:120 V )(designed for operation Line-Line. They may also be operated Line-Neutral at reduced voltage 58% of rated volts)         specs(click)

 

__________________________________________________________

3VT472  (-/+1 % at 5 VA, 60 Hz, 40 VA @ 30 Deg C, 120 to 600:120V) (designed for application to Y connected systems)   specs(click)

_______________________________________________________________________________________________________________________________________________

3VT468   (-/+ 0.6 % at 7.5 VA, 60Hz, 75 VA @ 30 Deg C, 69.3 to 346:120V) (designed for application to Y connected systems)        specs(click)

____________________________________________________________________________________________________________________

2VT460  (0.6 W, 1.2 X at 60 HZ, 150 VA @ 30 Deg C, 69.3 to 600:120 V)(designed for Open Delta Connection)      specs(click)

_____________________________________________________________________________________________________________________

3VTN460    (0.6 W, 1.2 X at 60 Hz, 150 VA @ 30 Deg C, 69.3 to 346:120V)(designed for operation Line to Neutral)          specs(click)

______________________________________________________________________________________________________________________

3VTL460    (0.6W, 1.2X at 60 Hz,  150 VA @ 30 Deg C, 120 to 600:120 V )(designed for Line-Line Operation)              specs(click)

 

___________________________________________________________________________________________

  • 469    (-/+ 1 % at 5 VA, 60 Hz, 40 VA @ 30 Deg C, 69.3 to 600:120 V )(designed for operation Line-Line. They may also be operated Line-Neutral at reduced voltage 58% of rated volts)         
  • 3VT472  (-/+1 % at 5 VA, 60 Hz, 40 VA @ 30 Deg C, 120 to 600:120V) (designed for application to Y connected systems)  
  • 3VT468   (-/+ 0.6 % at 7.5 VA, 60Hz, 75 VA @ 30 Deg C, 69.3 to 346:120V) (designed for application to Y connected systems)       
  • 2VT460  (0.6 W, 1.2 X at 60 HZ, 150 VA @ 30 Deg C, 69.3 to 600:120 V)(designed for Open Delta Connection)     
  • 3VTN460    (0.6 W, 1.2 X at 60 Hz, 150 VA @ 30 Deg C, 69.3 to 346:120V)(designed for operation Line to Neutral)         
  • 3VTL460    (0.6W, 1.2X at 60 Hz,  150 VA @ 30 Deg C, 120 to 600:120 V )(designed for Line-Line Operation)