Revenue Grade Current Transformers
Revenue Grade Current Transformers (CTs) approved for revenue metering by Industry Canada, offering superior performance and a robust design. These current transformers have CSA/UL approval, and are offered in the 600 V Class series.
Revenue Grade Current Transformers are designed for applications which require maximum accuracy and precision, and come in a variety of window sizes and current ratings.
A Current Transformer (CT) is a type of transformer that is used to reduce or multiply an alternating current (AC). It produces a current in its secondary which is proportional to the current in its primary.
Current Transformers, along with voltage or potential transformers, are instrument transformers. Instrument transformers scale the large values of current to small, standardized values that are easy to handle for measuring instruments and protective relays. The Instrument transformers isolate measurement or protection circuits from the high voltage of the primary system. These units provide a secondary current that is accurately proportional to the current flowing in its primary, presenting a negligible load to the primary circuit.
These units are the current sensing units of the power system and are used at generating stations, electrical substations, and in industrial and commercial electric power distribution.
Advantages of Current Transformers are that the units can measure high current easily, high electrical isolation, simple construction, and easy maintenance and installation.
Features:
- Designed for applications which require maximum accuracy & precision
- Superior performance and robust design
Applications:
Standards:
- Approved for revenue metering by Industry Canada
Approvals:
- CSA
__________________________________________________
SORTED BY Window Size below
__________________________________________________
2DARL 1 inch window, Leads (ratio 200-5 approved only)
__________________________________________________
5DARL 1.56 inch window, Leads (ratio 250-5 to 1000-5 approved)
_________________________________________________
192 1.75 inch window, Terminals (ratio 100-5 to 500-5 approved)
______________________________________________
112 2.25 inch window, Terminals (ratio 100-5 to 1200-5 approved)
________________________________________________
194 2.50 inch window, Terminals (ratio 150-5 to 2000-5 approved)
_______________________________________________
113 2.75 inch window, Terminals (ratio 200-5 to 1500-5 approved)
_______________________________________________
114 3.25 inch window, Terminals (ratio 150-5 to 1600-5 approved)
______________________________________________
8 3.25 inch window, Terminals or Leads (ratio 250-5 to 2500-5 approved)
_____________________________________________
100 4.00 inch window, Terminals (ratio 300-5 to 3000-5 approved)
_____________________________________________
115 4.00 inch window, Terminals (ratio 150-5 to 4000-5 approved)
______________________________________
117 4.62 inch window, Terminals (ratio 250-5 to 4000-5 approved)
_____________________________________
120 5.75 inch window, Terminals (ratio 300-5 to 4000-5 approved)
________________________________________

Revenue Grade Current Transformers
2DARL 1 inch window, Leads (ratio 200-5 approved only)
5DARL 1.56 inch window, Leads (ratio 250-5 to 1000-5 approved)
192 1.75 inch window, Terminals (ratio 100-5 to 500-5 approved)
112 2.25 inch window, Terminals (ratio 100-5 to 1200-5 approved)
194 2.50 inch window, Terminals (ratio 150-5 to 2000-5 approved)
113 2.75 inch window, Terminals (ratio 200-5 to 1500-5 approved)
114 3.25 inch window, Terminals (ratio 150-5 to 1600-5 approved)
8 3.25 inch window, Terminals or Leads (ratio 250-5 to 2500-5 approved)
100 4.00 inch window, Terminals (ratio 300-5 to 3000-5 approved)
115 4.00 inch window, Terminals (ratio 150-5 to 4000-5 approved)
117 4.62 inch window, Terminals (ratio 250-5 to 4000-5 approved)
120 5.75 inch window, Terminals (ratio 300-5 to 4000-5 approved)
- CSA